According to well x trol bladder type well tank air precharge.
Water well pressure tank psi.
The tank s steel shell supports the water weight to ensure water never sits in loose fitting vinyl or rubber bags that can fold crease and wear.
18 psig for models wx 101 and wx 102.
For example if you have a pressure switch setting of 30 50 psi you pressure measured at the top of the tank should read 28 psi.
Servicing your pressure tank.
Typical factory set air pressure on a bladder type residential well water tank is 18 psi.
Pressure switch limits are different on different types of pressure tanks such as 20 to 40 lbs psi 30 to 50 lbs.
You ve emptied the water in your tank so the pressure should be a little lower than your normal cut in pressure.
Use a car tire pressure gauge to measure pressure.
If your well tank is on a 40 60 pressure switch your pressure setting should be 38 psi.
Psi and 40 to 60 lbs psi.
Turn off the circuit dedicated to the well pump.
Note the psi setting on the pressure gauge when the pump turns on.
Once the pressure in the tank meets the 60 psi threshold pump cut out pressure the pressure switch will signal the water pump to stop pumping ceasing the influx of water into the tank.
The cut on pressure for the well pump is 30 psi so the pressure of the tank should have a pressure of 28 psi.
The most common cut in cut out configurations for pressure tanks are 30 50 and 40 60.
Find a water valve close to the pressure tank and open it to drain water out of the tank until the pump kicks on.
With the water pump off the pressure in the tank will remain at 60psi until more water in the house is used draining the tank once again.
Well x trol water pressure tanks are shipped from the factory with a standard precharge of.
Air can be added with a compressor or bicycle pump.
A home s average water pressure should lie between 40 and 60 psi.
You can charge the tank via the air valve using a car tire inflator a compressor or even a bike pump.
Pressurized well tank is constructed of deep drawn steel and features stainless steel waterway lining for durability.
In a well system with a bladder style pressure tank the well bladder pressure should be 2 psi lower than the cut in pressure for the well pump.
Most well tanks come set at 30 50.
Check pressure in the tank with your pressure gauge.
Test the air fill valve with an air pressure gauge and see where your pressure lies.
For those who need to increase this number.
This differs depending on your tank s pressure settings.
Some models may come with different pressure settings however.
Pressurized well tank the water worker 32 gal.
The lower number is the turn on point for the tank to bring in more water and the higher number shuts the pump off.